Author name: contact@devinevisiontech.com

CRT04104 Radiology and Imaging Equipment, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Equipment Knobs

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Equipment Knobs CRT04104 · Radiology and Imaging Equipment START READING NOTES Study Equipment Knobs using the sections below. Use the topic navigation to continue through Radiology and Imaging Equipment. Contents of This Topic At the end of the session students should be able to check equipment knobs for functional performance. Equipment Knobs Exposure Time Knob: Adjusts the duration of radiation exposure, impacting image clarity and patient dose. Collimation Knob: Controls the size and shape of the X-ray beam, limiting exposure to only the area of interest. Inspect for Wear and Tear: Cracks, looseness, or unusual resistance. Turn Each Knob Through Full Range: Test each knob’s entire range to identify inconsistencies or issues. Sanitize Equipment: Wipe down knobs and surrounding areas. Radiological knobs used on ultrasound machines: Probe selection knob – Allows switching between different ultrasound probes/transducers Wall filter control – Used in Doppler modes to filter out low-frequency signals. Equipment Knobs At the end of the session students should be able to check equipment knobs for functional performance. Learning objective Equipment Knobs Equipment knobs are small, manual controls located on machinery or devices that allow users to adjust various settings or functions. In radiology equipment, knobs often control parameters such as exposure levels, focus, alignment, and positioning, which are crucial for achieving accurate and high-quality imaging results. Definition Exposure Time Knob: Adjusts the duration of radiation exposure, impacting image clarity and patient dose. Voltage Control Knob (kVp Knob):Regulates the kilovolt peak (kVp), affecting the contrast and penetration level of the X-ray. Current Control Knob (mA Knob): Adjusts the milliampere (mA) setting, which controls the quantity of radiation and influences image brightness. Focus Control Knob: Allows precise adjustment of the focal spot, ensuring that the area of interest is sharp and clear. Examples of Equipment Knobs in Radiology: Collimation Knob: Controls the size and shape of the X-ray beam, limiting exposure to only the area of interest. Alignment/Positioning Knobs: Adjusts the positioning of the equipment to ensure accurate alignment with the target anatomy. Image Intensity Control Knob (for fluoroscopy):Allows real-time adjustment of image brightness during fluoroscopy procedures. Gain, TCG, Zoom, depth etc.(in ultrasound) These knobs are vital for tuning imaging equipment to meet specific diagnostic requirements while maintaining patient and operator safety. Examples cont….. X-ray knobs Ultrasound knobs Inspect for Wear and Tear: Cracks, looseness, or unusual resistance. Ensure Proper Labeling: Labels should be visible and accurately reflect knob function. Clean Knobs if Necessary: Prevents contamination and ensures accurate adjustments. Visual Inspection of Knobs Turn Each Knob Through Full Range: Test each knob’s entire range to identify inconsistencies or issues. Check Calibration (if applicable): Verify that the knob settings align with actual output (for calibrated knobs). Document Performance: Log any issues, unusual resistance, or deviations from expected performance. Functional Check of Knobs Sanitize Equipment: Wipe down knobs and surrounding areas. Store PPE and Tools Properly: Return tools to storage and dispose of PPE if necessary. Confirm SOP Completion: Sign off on checklist or digital log to confirm all steps completed. Post-Check Clean-Up Collimation Knob: Controls the size and shape of the X-ray beam, limiting exposure to only the area of interest. Alignment/Positioning Knobs: Adjusts the positioning of the equipment to ensure accurate alignment with the target anatomy. Image Intensity Control Knob (for fluoroscopy):Allows real-time adjustment of image brightness during fluoroscopy procedures. Gain, TCG, Zoom, depth,Freeze knobsetc.(in ultrasound) These knobs are vital for tuning imaging equipment to meet specific diagnostic requirements while maintaining patient and operator safety. Examples cont….. Radiological knobs used on ultrasound machines: Depth control knob – Adjusts how deep the ultrasound beam penetrates into the body. Gain control knob – Increases or decreases overall brightness/darkness of the image. Time Gain Compensation (TGC) / Depth Gain Compensation (DGC) knob – Allows adjusting gain at specific depths. Focus/focal zone control knob – Selects depth to focus ultrasound waves for improved lateral resolution. Sector size/width control knob – Adjusts the width of the image displayed on the screen. Probe selection knob – Allows switching between different ultrasound probes/transducers Probe frequency control – Lets you adjust the frequency of the ultrasound emitted by the probe Zoom/magnify control – Magnifies a selected region of the image Flip screen button – Flips the orientation of the displayed image Sweep speed control – Adjusts how many seconds are shown on the x-axis in M-mode Wall filter control – Used in Doppler modes to filter out low-frequency signals. Angle correction control – Helps compensate for the angle of insonation in Doppler modes. Auto function button – Automatically adjusts settings like gain. Preset/application selector – Allows selecting pre-configured settings for different. NOTE: These knobs allow users to optimize ultrasound images for different applications and body types Proper knob settings are crucial for obtaining high-quality diagnostic images The exact labels and locations of knobs may vary slightly between different ultrasound ← PREVIOUS TOPICNEXT TOPIC →VIEW ALL MODULE NOTESVIEW SEMESTER NOTESVIEW ALL LEVEL NOTESALL DIAGNOSTIC RADIOLOGY NOTES Need These Notes as PDF? Need a clean, well-formatted PDF copy for offline study, revision or printing? Request the complete notes directly through WhatsApp. GET WELL-FORMATTED PDF NOTES

CRT04104 Radiology and Imaging Equipment, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Tube Warming And Calibration

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Tube Warming And Calibration CRT04104 · Radiology and Imaging Equipment START READING NOTES Study Tube Warming And Calibration using the sections below. Use the topic navigation to continue through Radiology and Imaging Equipment. Contents of This Topic Learning objective: At the end of this session Students should be able to perform equipment tube warming and calibration. Tube Warming And Calibration Importance of calibration X-Ray Tubes Check Manufacturer Guidelines: Each equipment model may have unique requirements. Step 1: Access calibration settings (as guided by the manufacturer's protocol). Daily Calibration: Quick checks for routine operation, often automated. Enhanced Image Quality: Reliable and clear images for accurate diagnosis. Tube Warming and Calibration Learning objective: At the end of this session Students should be able to perform equipment tube warming and calibration. Introduction Tube Warming And Calibration Tube Warming: Is the process of gradually increasing the voltage and current of an x-ray tube to prepare it for use. Tube warming ensure the tube is operating at optimal temperature for efficient and safe image production. Importance of tube warming Minimizes thermal stress Prevents damage Ensures stable operation. Tube Warming Tube Warming And Calibration Calibration: Is the process of evaluating and adjusting the accuracy of measurement devices to ensure precise and accurate readings. Calibration enhances and verify the accuracy of the machines exposure parameters (kvp,MA,time). Calibration Importance of calibration Image quality: Ensure consistent and accurate image production. Patient safety: To prevent overexposure or underexposure, which can lead to diagnostic errors or patient harm. Regulatory compliance: Adheres to radiation safety standards and regulations. X-Ray Tubes CT Scanners MRI Machines (e.g, coil calibration) Portable Imaging Devices Special Radiology Equipment (e.g, fluoroscopy, mammography machines) Equipment Requiring Warming and Calibration Check Manufacturer Guidelines: Each equipment model may have unique requirements. PPE and Safety Precautions: Adhere to safety protocols (e.g, lead aprons, dosimeters). Environment Preparation: Ensure room temperature and ventilation are optimal for equipment operation. Preparation for Tube Warming and Calibration Tube Warming And Calibration Step 1:Power on, turn on the equipment and allow it to idle, select the appropriate exposure settings as recommended by the manufacturer. Step 2:Initial exposure, make a few low dose-dose exposures to warm up the tube and to avoid thermal shock. Step 3:Monitoring, Observe the tubes temperature indicator or monitor. Step 4: Completion, once the tube reaches a stable operating temperature, proceed with calibration or imaging. SOPs for Equipment Tube Warming Step 1: Access calibration settings (as guided by the manufacturer's protocol). Step 2: Perform initial checks on positioning and alignment, if applicable. Step 3: Conduct calibration procedures (voltage adjustments, software calibration, phantom testing for accuracy). Step 4: Validate calibration results and document findings. Step 5: Make necessary adjustments as indicated by calibration feedback. Calibration Procedure for Radiology Equipment Daily Calibration: Quick checks for routine operation, often automated. Weekly Calibration: More comprehensive, may include phantom testing for accuracy. Quarterly/Annual Calibration: Full diagnostic and performance calibration, often conducted by certified technicians. Calibration frequency Enhanced Image Quality: Reliable and clear images for accurate diagnosis. Extended Equipment Life: Reduces wear and tear on high-cost radiology equipment. Patient Safety: Reduces exposure to retakes or unnecessary radiation. Benefits of Consistent Tube Warming and Calibration Tube Warming And Calibration Documentation: Maintain detailed records of warming and calibration event(procedures results, and any adjustments made) with date, time, and technician name. Training: Ensure that personnel are properly trained in tube warming and calibration techniques. Maintenance: Regular maintenance of radiographic machine is essential for optimal performance and calibration accuracy. Considerations Equipment Tube Warming and Calibration ← PREVIOUS TOPICNEXT TOPIC →VIEW ALL MODULE NOTESVIEW SEMESTER NOTESVIEW ALL LEVEL NOTESALL DIAGNOSTIC RADIOLOGY NOTES Need These Notes as PDF? Need a clean, well-formatted PDF copy for offline study, revision or printing? Request the complete notes directly through WhatsApp. GET WELL-FORMATTED PDF NOTES

CRT04104 Radiology and Imaging Equipment, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Equipment Cleaning

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Equipment Cleaning CRT04104 · Radiology and Imaging Equipment START READING NOTES Study Equipment Cleaning using the sections below. Use the topic navigation to continue through Radiology and Imaging Equipment. Contents of This Topic Learning Objectives Staff safety: To prevent contaminations of technicians with machines. X-Ray Machines Approved Cleaning Agents: Hospital-grade disinfectants, alcohol wipes. Step 1: Wear appropriate PPE before handling equipment. X-Ray Machines: Focus on the tube head, control panels, and patient positioning surfaces. Daily: High-touch surfaces and patient contact areas after each use. Checklist Completion & Reporting Issues : Approved Cleaning Agents: Hospital-grade disinfectants, isopropyl alcohol wipes. Wear proper personal protective equipment (PPE) including masks, gloves, and eye protection when cleaning/disinfecting equipment. Radiology Standard Operating Procedures(SOPs) for Equipment Cleaning Learning Objectives Students should understand the standardized cleaning procedures and protocols commonly used to clean radiology equipment's. Students should be able to explain the Importance of cleanliness in radiology. Students should be able to perform equipment cleaning. Introduction Staff safety: To prevent contaminations of technicians with machines. Patient Safety: Prevents infection and cross-contamination. Image Quality: Clean equipment ensures accurate diagnostic imaging and prevent equipment damage. Importance of Cleaning Radiology Equipment X-Ray Machines CT Scanners MRI Machines Ultrasound Equipment Nuclear imaging machines Portable Imaging Devices Common Equipment Requiring Regular Cleaning Approved Cleaning Agents: Hospital-grade disinfectants, alcohol wipes. Personal Protective Equipment (PPE): Gloves, masks, gowns if needed. Storage and Disposal: Safe storage of chemicals and disposal of used wipes/PPE. Cleaning Supplies and PPE Step 1: Wear appropriate PPE before handling equipment. Step 2: Turn off and unplug equipment when possible. Step 3: Clean high-touch surfaces with approved disinfectants (handles, buttons, screens). Step 4: Wipe down and disinfect patient contact areas. Step 5: Allow adequate drying time before next use General Cleaning SOP for Radiology Equipment X-Ray Machines: Focus on the tube head, control panels, and patient positioning surfaces. MRI Machines: Special considerations for non-ferromagnetic cleaning supplies; avoid moisture near the magnet. Ultrasound Equipment: Clean transducers, probes, and touch screens with compatible agents. Detailed Cleaning SOP for Specific Equipment Daily: High-touch surfaces and patient contact areas after each use. Weekly: Deep cleaning of all external parts. Monthly/Quarterly: Comprehensive internal and external equipment inspection (by qualified technicians). Frequency of Cleaning Checklist Completion & Reporting Issues : Record cleaning activities for each piece of equipment and report any damage or malfunctions found during cleaning. NB: Ensure all staff are following proper cleaning SOPs. Quality Assurance & Documentation Staff safety: To prevent contaminations of technicians with machines. Patient Safety: Prevents infection and cross-contamination. Image Quality: Clean equipment ensures accurate diagnostic imaging and prevent equipment damage. Increase lifespan of machines Importance of Cleaning Radiology Equipment Approved Cleaning Agents: Hospital-grade disinfectants, isopropyl alcohol wipes. Personal Protective Equipment (PPE): Gloves, masks, gowns if needed. Storage and Disposal: Safe storage of chemicals and disposal of used wipes/PPE. Cleaning Supplies and PPE Wear proper personal protective equipment (PPE) including masks, gloves, and eye protection when cleaning/disinfecting equipment. Switch off the equipment at the main power source before cleaning. Follow manufacturer instructions for specific cleaning agents and methods recommended for each type of equipment. Clean all surfaces thoroughly before disinfecting, removing any visible dirt or debris. Allow adequate drying time after cleaning/disinfection before restarting equipment. ← PREVIOUS TOPICNEXT TOPIC →VIEW ALL MODULE NOTESVIEW SEMESTER NOTESVIEW ALL LEVEL NOTESALL DIAGNOSTIC RADIOLOGY NOTES Need These Notes as PDF? Need a clean, well-formatted PDF copy for offline study, revision or printing? Request the complete notes directly through WhatsApp. GET WELL-FORMATTED PDF NOTES

CRT04104 Radiology and Imaging Equipment, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Care Of Radiology Equipments

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Care Of Radiology Equipments CRT04104 · Radiology and Imaging Equipment START READING NOTES Study Care Of Radiology Equipments using the sections below. Use the topic navigation to continue through Radiology and Imaging Equipment. Contents of This Topic Learning objective Overview of Radiology and Imaging Equipment Preventive Maintenance Daily Care: Importance of Calibration: Maintenance Logs: Summary of Key Points: Continuous education and training are vital to keep up with technological advancements. CARE OF DIFFERENT RADIOLOGY AND IMAGING EQUIPMENT Learning objective At the end of this session students must be able to correctly determine care of different radiology and imaging equipment. Overview of Radiology and Imaging Equipment Types of equipment: X-ray, CT scan, MRI, Ultrasound, etc. Importance of equipment care: ensuring safety, efficiency, and longevity. The role of radiologic technologists and healthcare professionals in equipment maintenance. Introduction Preventive Maintenance Regular checks and calibration Manufacturer's maintenance schedules Importance of documentation and logs Safety Protocols Radiation safety Electrical safety Infection control measures General Principles of Radiology Equipment Care Daily Care: Check for cleanliness and proper functioning of the tube and detectors. Ensure accurate calibration of radiation dose. Visual inspection for signs of wear or damage. Preventive Maintenance: Scheduled servicing by certified professionals. Regular checks on mechanical parts like collimators and tube positioning. Software updates and calibration. Care of X-ray Equipment Daily Care: Inspect for cleanliness and debris in the scanning area. Verify system functionality and image quality. Ensure proper alignment of patient positioning equipment. Preventive Maintenance: Routine checks on the gantry, detector array, and x-ray tube. Regular calibration for radiation dose and image clarity. Software updates and quality control tests. Care of Computed Tomography (CT) Scanners Daily Care: Monitor for any unusual noise or malfunctions. Check the superconducting magnet’s cooling system. Ensure proper shielding to prevent interference. Preventive Maintenance: Periodic cooling system checks. Calibration of magnetic field strength. Inspection of gradient coils and RF coils for performance Care of Magnetic Resonance Imaging (MRI) Equipment Daily Care: Clean the transducers after each use to avoid infection. Check the cables and transducer surface for wear or damage. Inspect display screens for clarity. Preventive Maintenance: Regular calibration of image quality. Firmware updates. Periodic assessment of transducer performance Care of Ultrasound Machines Daily Care: Check the image quality and radiation dose levels. Clean the C-arm and ensure proper positioning. Ensure the safety interlocks are functioning properly. Preventive Maintenance: Routine checks on imaging plates and radiation detectors. Monitor and adjust exposure settings. Regular calibration of image processing software. Care of Fluoroscopy Equipment Importance of Calibration: Ensures image accuracy and diagnostic reliability. Reduces radiation exposure to patients. Promotes consistency in image quality. Quality Control Tests: Regular imaging phantoms to test for precision. Calibration tools for consistent measurements. Software checks for system integrity. Calibration and Quality Control Maintenance Logs: Track dates of maintenance and repairs. Document calibration and testing results. Ensure compliance with regulatory standards. Service Reports: Maintain detailed service reports from professional technicians. Review operational trends to predict potential issues. Documentation and Record Keeping Summary of Key Points: Regular care, maintenance, and calibration are essential for optimal performance. Safety protocols are crucial in preventing accidents and ensuring effective imaging. Proper documentation and adherence to service schedules prolong equipment life and enhance diagnostic accuracy. Conclusion Continuous education and training are vital to keep up with technological advancements. Effective teamwork between technologists, engineers, and healthcare professionals ensures high-quality patient care. Conclusion… ← PREVIOUS TOPICNEXT TOPIC →VIEW ALL MODULE NOTESVIEW SEMESTER NOTESVIEW ALL LEVEL NOTESALL DIAGNOSTIC RADIOLOGY NOTES Need These Notes as PDF? Need a clean, well-formatted PDF copy for offline study, revision or printing? Request the complete notes directly through WhatsApp. GET WELL-FORMATTED PDF NOTES

CRT04104 Radiology and Imaging Equipment, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Imaging Modalities

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Imaging Modalities CRT04104 · Radiology and Imaging Equipment START READING NOTES Study Imaging Modalities using the sections below. Use the topic navigation to continue through Radiology and Imaging Equipment. Contents of This Topic OBJECTIVES Determine care of different radiology and imaging equipment. Understand operation of fluoroscopic machine to examine patient. RADIOLOGY INTRODUCTION X RAY IMAGING Imaging Modalities Origin of X-ray Source remains same for all x-ray imaging devices Bone APPLICATION OF X RAY Advantage of x ray imaging ULTRASOUND IMAGING Ultrasound machines Components Pulse controls: Dials and controls that are used to change the amplitude, frequency, and duration of ultrasound pulses. Types of ultrasound transducer Components cont……….. Ultrasound gel IMAGE FORMATION IN ULTRASOUND APPLICATION OF ULTRASOUND Advantage of ultrasound 2. Non-invasive Approach 3. PAINLESS 4. NO RECOVERY TIME 5. COST SOFT TISSUE DETAILS DIFFERENCE BETWEEN X RAY AND ULTRASOUND FLUOROSCOPY X RAY MACHINE Fluoroscopy Mammography Mammography vs mammogram 3D Mammography 3D Mammogram A) Dental (Intra-oral x-ray examination) COMPUTED TOMOGRAPHY (CT) CT Cont……. CT image formation During a CT scan, x-ray projections are taken from many angles around the patient. Magnetic resonance imaging(MRI) MRI Cont….. Simplified working principle of MRI Bone Mineral Densitometry Equipment Echography is a rare synonym but is seen especially concerning the ultrasound of the eye. 6. SOFT TISSUE DETAILS RADIOLOGY AND IMAGING EQUIPMENT OBJECTIVES Expected learning outcomes: At the end of the course/module students will be able to: Identify different radiology and imaging modalities. Component of convectional x ray and their functions Describe component and functions of dental equipment Determine care of different radiology and imaging equipment. Identify accessories for radiological investigations To understand operation of x ray machine to examine patients To understand operation of dental x ray machine to examine patient. Understand operation of fluoroscopic machine to examine patient. Understand conducting quality control procedures for x ray machine. Understand conducting of basic quality control procedures for dental x ray machine. To maintain record events of all equipment for maintenance and servicing. RADIOLOGY Branch of medical science that deals with the use of radiant energy in the diagnosis and treatment disease. INTRODUCTION Medical imaging plays a crucial role in diagnosing and monitoring a wide range of medical conditions. Among the most common imaging techniques are X-ray, ultrasound, CT scan MRI, and radionuclide scan X ray modality can be classified into Dental x ray Mammography Fluoroscopy x ray machine X RAY IMAGING X-ray imaging, uses ionizing radiation to produce detailed images of the body's interior. X-ray Machine: A machine emits a controlled amount of X-ray radiation through the body. Absorption: Dense structures, like bones and tumors, absorb more X-rays, resulting in white areas on the X-ray image. Image Capture: X-rays that pass through the body are captured on a detector, creating an image. Imaging Modalities Medical imaging of the human body requires some form of energy (radiation). In imaging techniques used in radiology, the energy used to produce the image must be capable of penetrating tissues. In diagnostic X-ray imaging, images are formed by the interaction of the X-ray beam with the patient. As the X-ray beam passes through the patient, the photons interact with the body tissues and are absorbed/scattered by the patient. The degree of absorption is related to the density of the material that is in the beam’s path. Dense objects (such as bone and metal) have a high degree of photon absorption, while less dense objects (such as fat and water) absorbs less photons. The differential absorption of photons by different materials in the photons' path results in the beam exiting the patient with different intensities. This is known as transmitted beam. A detector is used to measure the intensity variation, thus providing information on the different densities in the beam’s path. Origin of X-ray Source remains same for all x-ray imaging devices i.e X-ray tube Evacuated glass tube Target Filament Imaging Modalities Radiography X-ray equipment has an x-ray tube on one side and an x-ray detector on the other side of the patient. A short duration pulse of x-rays is emitted by the x-ray tube, a large fraction of the x- rays interacts in the patient, some of the x-rays pass through the patient (transmitted x-rays) and reach the detector. These transmitted x-rays form the radiographic image on the film/detector. In radiography, the image is formed with screen-film system, CR cassette or with digital detectors. In screen-film radiography, areas of high intensity (thus low material absorption) within transmitted beam result in more blackening of the film, while areas of low intensity (thus high material absorption) will result in less blackening of the film. The film will remain white in areas with no photons. Human body is made up of tissues with varying densities, in the film black corresponds to tissues with little attenuation (such as air) and white corresponds to tissue with a high degree of attenuation (such as bone). Bone Air Soft tissue X Primary collimation Film, fluorescent screen or image intensifier Beam intensity at detector level « Latent » radiological Image formed Antiscatter Grid Scattered radiation X-ray Image Formation APPLICATION OF X RAY Orthopedics: X-rays are commonly used to detect fractures, bone diseases, and joint problems. Dental: Dental X-rays are essential for diagnosing oral health issues. Chest Imaging: It helps diagnose lung conditions like pneumonia and lung cancer. Mammography: X-ray mammography is used for breast cancer screening. Advantage of x ray imaging noninvasively and painlessly help to diagnose disease and monitor therapy; support medical and surgical treatment planning; and Guide medical personnel as they insert catheters, stents, or other devices inside the body, treat tumors, or remove blood clots or other blockages ULTRASOUND IMAGING Ultrasound imaging, relies on high frequence sound(ultrasonic) waves to create real-time images of the body's internal structures. Ultrasound is the most common term used for this modality however occasionally ultrasonography (USG), or just sonography are used. When abbreviated, USS, short for ultrasound scanning, may be used as an alternative. Ultrasound images are produced by relying on

CRT04103 Radiographic Techniques and Procedures, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Wrist Joint

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Wrist Joint CRT04103 · Radiographic Techniques and Procedures START READING NOTES Study Wrist Joint using the sections below. Use the topic navigation to continue through Radiographic Techniques and Procedures. Contents of This Topic WRIST JOINT WRIST POSTERO-ANTERIOR Direction and Centering of X-ray Beam Essential Image Characteristics Notes; LATERAL Note Scaphoid For scaphoid fractures, three or more projections may be taken: A; SCAPHOID – POSTERO-ANTERIOR B;SCAPHOID – ANTERIOR OBLIQUE Direction and Centring of X-ray Beam C;SCAPHOID – POSTERIOR OBLIQUE D.SCAPHOID POSTERO-ANTERIOR – Radiological Considerations E. Scaphoid – Lateral Direction and location of the X-ray beam Carpal tunnel Axial – method 1 Direction and location of X-ray beam Axial – method 2 (Fig. 2.17b) WRIST JOINT Mdu RADIOGRAPHIC ANATOMY WRIST Basic Projection POSTERO-ANTERIOR LATERAL POSTERO-ANTERIOR Position of Patient and Image Receptor The patient is seated alongside the table, with the affected side nearest to the table. The elbow joint is flexed to 90 degrees and the arm is abducted, such that the anterior aspect of the forearm and the palm of the hand rests on the image receptor. If the mobility of the patient permits, the shoulder joint should be at the same height as the forearm. The wrist joint is placed central to the image receptor and adjusted to include the lower part of the radius and ulna and the proximal two-thirds of the metacarpals. The fingers are flexed slightly to bring the anterior aspect of the wrist into contact with the image receptor. The wrist joint is adjusted to ensure that the radial and ulnar styloid processes are equidistant from the image receptor. The forearm is immobilized using a sandbag. Direction and Centering of X-ray Beam The vertical central ray is centred to a point midway between the radial and ulnar styloid processes. Essential Image Characteristics The image should demonstrate the proximal two-thirds of the metacarpals, the carpal bones, and the distal third of the radius and ulna. There should be no rotation of the wrist joint. Notes; When the image is undertaken for a scaphoid view the wrist should be in ulnar deviation. LATERAL Position of Patient and Image Receptor The patient is seated alongside the table, with the affected side nearest to the table. The elbow joint is extended to bring the medial aspect of the forearm, wrist and hand into contact with the table. The wrist joint is positioned to include the lower part of the radius and ulna and the proximal two-thirds of the metacarpals on the image receptor. The hand is rotated externally slightly further to ensure that the radial and styloid processes are superimposed. The forearm is immobilized using a sandbag. Direction and Centering of X-ray Beam The vertical central ray is centered over the styloid process of the radius Note If the elbow is extended rather than at right-angles it is often easier to rotate the wrist into a lateral position. CAPAL BONES Scaphoid Imaging of the carpal bones is most commonly undertaken to demonstrate the scaphoid. For suspected scaphoid fractures, three or more projections may be taken The projections may also be used to demonstrate other carpal bones; For scaphoid fractures, three or more projections may be taken: A carpal fracture is a break of one of the eight small bones of the carpus. These bones are the scaphoid, lunate, capitate, triquetrum, hamate, pisiform, trapezium, and trapezoid. Fractures of the other carpal bones do occur but the scaphoid is accountable for 60–70% of fractures of the carpal bones. A; SCAPHOID – POSTERO-ANTERIOR WITH ULNAR DEVIATION Position of patient and image receptor The patient is seated alongside the table with the affected side nearest the table. The arm is extended across the table with the elbow flexed and the forearm pronated. If possible, the shoulder, elbow and wrist should be at the level of the tabletop. The wrist is positioned over the centre of the image receptor and the hand is adducted (ulnar deviation). Ensure that the radial and ulnar styloid processes are equidistant from the image receptor. The hand and lower forearm are immobilized using sandbags.. Direction and Centering of X-ray Beam The vertical central ray is centred midwa between the radial and ulnar styloid processes. Essential Image Characteristics The image should include the distal end of the radius and ulna and the proximal end of the metacarpals. The joint space around the scaphoid should be demonstrated clearly. B;SCAPHOID – ANTERIOR OBLIQUE WITH ULNAR DEVIATION Position of Patient and Image Receptor From the postero-anterior position, the hand and wrist are rotated 45 degrees externally and placed central over an image receptor. The hand should remain adducted in ulnar deviation. The hand is supported in position, with a non-opaque pad placed under the thumb. The forearm is immobilized using a sandbag. Direction and Centring of X-ray Beam The vertical central ray is centred midway between the radial and ulnar styloid processes. Essential Image Characteristics The image should include the distal end of the radius and ulna and the proximal end of the metacarpals. The scaphoid should be seen clearly, with its long axis parallel to the image receptor RADIOGRAPHIC ANATOMY WITH ULNA DEVIATION C;SCAPHOID – POSTERIOR OBLIQUE Position of Patient and Image Receptor From the anterior oblique position, the hand and wrist are rotated externally through 90 degrees, such that the posterior aspect of the hand and wrist are at 45 degrees to the image receptor. The wrist is then supported on a 45-degree no- opaque foam pad. The forearm is immobilized using a sandbag. Direction and Centering of X-ray Beam The vertical central ray is centred over the styloid process of the ulna. Essential Image Characteristics The image should include the distal end of the radius and ulna and the proximal end of the metacarpals. The pisiform should be seen clearly in profile situated anterior to the triquetral. The long axis of the scaphoid should be seen perpendicular to the image receptor D.SCAPHOID POSTERO-ANTERIOR – ULNAR DEVIATION AND 30-DEGREE CRANIAL ANGLE The

CRT04103 Radiographic Techniques and Procedures, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Vertebral Column

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Vertebral Column CRT04103 · Radiographic Techniques and Procedures START READING NOTES Study Vertebral Column using the sections below. Use the topic navigation to continue through Radiographic Techniques and Procedures. Contents of This Topic USEFUL LANDMARKS The inferior angle of the scapula indicates the level of T7 when the arms are placed by the side. The lower costal margin indicates L3 and is located easily. The anterior and posterior iliac spines lie at the level of the second sacral vertebra. CERVICAL SPINE LATERAL VIEW • To aid immobilization, the patient should stand with the feet Direction and centering of the X-ray beam Essential image characteristics Position of patient and cassette Vertebral Column LATERAL THORACIC SPINE • The arms should be raised well above the head. • The trabecular of the vertebrae should be clearly visible, demonstrating an absence of movement unsharpness. 1.UNDERLINED ANATOMY Vertebral levels Angle of mandible 2-3 CV Radiation protection CERVICAL VERTEBRAE Preparation of the patient Basic views Antero-posterior – first ,second and 3rd Direction and centring of the X-ray beam Antero-posterior third to seventh Axial – upper cervical vertebra Lateral supine Addition view Oblique projections are requested mainly to supplement the basic projections in cases of trauma. Cervico-thoracic vertebrae(Lateral swimmers’) Thoracic vertebrae AP Position of patient and cassette The anode heel effect can also be exploited by positioning the anode cranially and the cathode caudally. Heel effect Lumbar vertebrae Lumbo-sacral junction Antero-posterior Sacrum Lateral Coccyx RADIOGRAPHIC PROCEDURE OF THE VERTEBRAL COLUMN USEFUL LANDMARKS The easily palpated tip of the mastoid process indicates the level of C1. The spinous process of C7 produces a visible protuberance on the posterior aspect of the inferior part of the neck. Below this, the spinous process of the thoracic spine can be palpated. NB: the thoracic spinous processes are directed steeply downwards, so their palpable tips will be adjacent to the vertebral body below. The inferior angle of the scapula indicates the level of T7 when the arms are placed by the side. The sternal notch lies at the junction between T2 and T3. T4 is indicated by the sternal angle with T9 corresponding to the xiphisternal joint, although the size of this structure is variable. The lower costal margin indicates L3 and is located easily. This is a very useful aid to positioning in spinal radiography. A line joining the most superior parts of the iliac crests indicates the level of L4, whilst the tubercle of the iliac crest discloses the location of L5. The anterior and posterior The anterior and posterior iliac spines lie at the level of the second sacral vertebra. The coccyx can be palpated between the buttocks and lies at the level of the symphysis pubis. CERVICAL SPINE LATERAL VIEW Position of patient and cassette The patient stands or sits with either shoulder against the cassette. The median sagittal plane should be adjusted such that it is parallel with the cassette. The head should be flexed or extended such that the angle of the mandible is not superimposed over the upper anterior cervical vertebra or the occipital bone does not obscure the posterior arch of the atlas. • To aid immobilization, the patient should stand with the feet slightly apart and with the shoulder resting against the cassette stand. In order to demonstrate the lower cervical vertebra, the shoulders should be depressed, This can be achieved by asking the patient to relax their shoulders downwards. The process can be aided by asking the patient to hold a weight in each hand (if they are capable) and making the exposure on arrested expiration. Direction and centering of the X-ray beam The horizontal central ray is centred to a point vertically below the mastoid process at the level of the prominence of the thyroid cartilage. Essential image characteristics The whole of the cervical spine should be included, from the atlanto-occipital joints to the top of the first thoracic vertebra. The mandible or occipital bone does not obscure any part of the upper vertebra. Angles of the mandible and the lateral portions of the floor of the posterior cranial fossa should be superimposed. Soft tissues of the neck should be included. The contrast should produce densities sufficient to demonstrate soft tissue and bony detail. Position of patient and cassette The patient is positioned supine on the X-ray table, with the median sagittal plane perpendicular to the tabletop and coincident with the midline of the Bucky. The upper edge of a cassette, which should be at least 40 cm long for an adult, should be at a level just below the prominence of the thyroid cartilage to ensure that the upper thoracic vertebrae are included. Vertebral Column Make exposure on arrested inspiration. This will cause the diaphragm to move down over the upper lumbar vertebra, thus reducing the chance of a large density difference appearing on the image from superimposition of the lungs. Direction and centering of the X-ray beam Direct the central ray at right-angles to the cassette and towards a point 2.5 cm below the sternal angle. Collimate tightly to the spine. Essential image characteristics The image should include the vertebrae from C7 to L1. The image density should be sufficient to demonstrate bony detail for the upper as well as the thoracic lower vertebrae. LATERAL THORACIC SPINE Usually undertaken with the patient in the lateral decubitus position on the X-ray table, although this projection can also be performed erect. The median sagittal plane should be parallel to the cassette and the midline of the axilla coincident with the midline of the table or Bucky. • The arms should be raised well above the head. The head can be supported with a pillow, and pads may be placed between the knees for the patient’s comfort. The upper edge of the cassette should be at least 40 cm in length and and should be positioned 3–4 cm above the spinous process of C7. Direction and centering of the X-ray beam The

CRT04103 Radiographic Techniques and Procedures, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

The Vertebral Column

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE The Vertebral Column CRT04103 · Radiographic Techniques and Procedures START READING NOTES Study The Vertebral Column using the sections below. Use the topic navigation to continue through Radiographic Techniques and Procedures. Contents of This Topic 1.UNDERLINED ANATOMY The Vertebral Column Vertebral levels Angle of mandible 2-3 CV Radiation protection CERVICAL VERTEBRAE Preparation of the patient Basic views Antero-posterior – first ,second and 3rd Position of patient and cassette Direction and centring of the X-ray beam Antero-posterior third to seventh Axial – upper cervical vertebra Direction and centering of the X-ray beam Lateral supine Addition view Oblique projections are requested mainly to supplement the basic projections in cases of trauma. Cervico-thoracic vertebrae(Lateral swimmers’) THORACIC VERTEBRAE AP Position of patient and cassette The anode heel effect can also be exploited by positioning the anode cranially and the cathode caudally. Heel effect LUMBAR VERTEBRAE LUMBO-SACRAL JUNCTION Lateral Antero-posterior SACRUM COCCYX THE VERTEBRAL COLUMN 1.UNDERLINED ANATOMY The vertebral column consist of 33 vertebrae, 7cervical ,12 thoracic, 5 lumbar ,5 sacral and 4 coccygeal The coccygeal segments in some cases are three fused together and form a triangular bone. The vertebrae in each region show variation from basic pattern. Each region demands its own technique to demonstrate it. When dealing with radiographic technique of the vertebral column, the following terminologies should be remembered; Kyphosis-abnormal backward bending of the spine Lordosis -abnormal forward bending of the spine Scoliosis-abnormal lateral bending of the spine The Vertebral Column Most of the examination in the vertebral column need a Bucky or stationary grid except the lateral view of the cervical spine. Arrested respiration for this examination of this region is necessary After routine examination of part of the vertebral column, the doctor may request a coned view of particular vertebrae At least three to five vertebrae should be be covered in coned view views Vertebral levels Some useful landmarks Angle of mandible 2-3 CV Sternal notch 2-3 DV Sternal angle 4-5 DV Xiphisternal junction 9-4DV Lower coastal margin 3-4 LV Umbilicus 3-4 LV Iliac crest 4 LV ASIS 2 sacral Symphysis pubis-1st piece of coccyx Radiation protection With the exception of lumbo-sacral region and sacrum in female patients, it is always possible to protect the gonads from direct radiation by accurate conning and lead rubber placed over the gonad area The ten day rule should be observed for female patients of child bearing age. Note; the vertebral column of a child may be shown almost completely on one film. demonstration CERVICAL VERTEBRAE The cervical spine is convex forwards. The seven cervical vertebrae show marked differences from each other, particularly the first(atlas)which has an anterior arch instead of vertebral body,into which first the odontoid peg of the second CV (AXIS). In the AP view, the upper CV is obscured by the jaws and occiput . But they can be demonstrated if this view is taken with patients mouth open. Preparation of the patient Remove dentures, hairpins and neck and ear ornaments.. The patients should undress and given the x -ray gown Basic views AP (CV 1-3) AP ( CV 3-7) Lateral view Antero-posterior – first ,second and 3rd cervical vertebrae (open mouth) Position of patient and cassette The patient lies supine on the Bucky table or, if erect positioning is preferred, sits or stands with the posterior aspect of the head and shoulders against the vertical Bucky. The medial sagittal plane is adjusted to coincide with the midline of the cassette, such that it is at right-angles to the cassette. The neck is extended, if possible, such that a line joining the tip of the mastoid process and the inferior border of the upper incisors is at right-angles to the cassette. This will superimpose the upper incisors and the occipital bone, thus allowing clear visualization of the area of interest. The cassette is centered at the level of the mastoid process Direction and centring of the X-ray beam Direct the perpendicular central ray along the midline to the center of the open mouth. If the patient is unable to flex the neck and attain the position described above, then the beam must be angled, typically five to ten degrees cranially or caudally, to superimpose the upper incisors on the occipital bone. The cassette position will have to be altered slightly to allow the image to be centered after beam angulation. Antero-posterior third to seventh vertebrae Position of patient and cassette The patient lies supine on the Bucky table or, if erect positioning is preferred, sits or stands with the posterior aspect of the head and shoulders against the vertical Bucky. The median sagittal plane is adjusted to be at right-angles to the cassette and to coincide with the midline of the table or Bucky. The neck is extended (if the patient’s condition will allow) so that the lower part of the jaw is cleared from the upper cervical vertebra. The cassette is positioned in the Bucky to coincide with the central ray. The Bucky tray will require some cranial displacement if the tube is angled. Direction and centring of the X-ray beam A 5–15-degree cranial angulation is employed, such that the inferior border of the symphysis menti is superimposed over the occipital bone. The beam is centered in the midline towards a point just below the prominence of the thyroid cartilage through the fifth cervical vertebra. Axial – upper cervical vertebra This is a useful projection if the odontoid peg cannot be demonstrated using the open mouth projection. Remember that the neck must not be flexed in acute injuries. Position of patient and cassette The patient lies supine on the Bucky table, with the median sagittal plane coincident with the midline of the table and at right-angles to the cassette. The neck is extended so that that the orbito-meatal baseline is at 45 degrees to the tabletop. The head is then immobilized. The cassette is displaced cranially so that its centre coincides with the central ray. Direction and centering of

CRT04103 Radiographic Techniques and Procedures, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Standard Operating Procedures for Radiology Room Preparation

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Standard Operating Procedures for Radiology Room Preparation CRT04103 · Radiographic Techniques and Procedures START READING NOTES Study Standard Operating Procedures for Radiology Room Preparation using the sections below. Use the topic navigation to continue through Radiographic Techniques and Procedures. Contents of This Topic What is standard operating procedures Important of SOPs Standard Operating Procedures for Radiology Room Preparation What can occur when SPOs are not followed Responsibilities Performing equipment cleaning E.g. of steps of cleaning mashine Room Cleaning Important of performing cleaning 4. Compliance with Health Standards Performing Equipment Tube Warming and Calibration Importance of Tube Warming and Calibration in Radiology Equipment Calibration Tube Warming Procedures Steps for Warming X-ray Tubes: Gradually Increase Exposure: Equipment Calibration Procedures Special Considerations for Tube Warming and Calibration Importance of Checking Equipment Knobs for Functional Performance Types of Knobs and Controls on Radiology Equipment Steps for Checking Equipment Knobs for Functional Performance Functional Testing of Knobs Test Each Knob's Response CONT… Calibration of Knob Function (If Required) Preventive Maintenance for Knobs and Controls Importance of Checking Electrical Gadgets and Plugs Steps for Checking Electrical Gadgets and Plugs for Connectivity and Functionality Troubleshooting Electrical Connectivity Issues Safety Considerations for Handling Electrical Gadgets Standard operation procedures for room preparation in preparing radiology and imaging room for patient investigation What is standard operating procedures is a set of step-by step instructions or guideline the explains how to perform specific task Creating Standard Operating Procedures (SOPs) for room preparation in a radiology and imaging department is essential for ensuring patient safety, equipment functionality, and overall efficiency. Important of SOPs Standard Operating Procedures (SOPs) are crucial for several reasons: Consistency: SOPs ensure that tasks are performed consistently across an organization, leading to uniform quality and results. Efficiency: By providing clear instructions, SOPs streamline processes, reducing time spent on training and minimizing errors. Compliance: They help organizations adhere to regulatory requirements and industry standards, ensuring legal compliance and reducing the risk of penalties. Safety: SOPs establish safety protocols, protecting employees and reducing workplace hazards. Standard Operating Procedures for Radiology Room Preparation Training Tool: They serve as valuable resources for onboarding new employees, providing a clear framework for job responsibilities. Accountability: SOPs define roles and responsibilities, making it easier to hold team members accountable for their tasks. Quality Control: They help maintain high standards of quality by providing a benchmark for performance evaluation. Continuous Improvement: SOPs can be regularly reviewed and updated to incorporate feedback and improve processes over time. What can occur when SPOs are not followed Inconsistent Quality: Variability in processes can lead to inconsistent product or service quality, damaging reputation and customer trust. Increased Errors: Without clear guidelines, employees may make mistakes more frequently, resulting in rework, waste, and potential safety hazards. Compliance Issues: Failing to adhere to SOPs can lead to violations of regulatory requirements, risking legal repercussions and fines. Safety Risks: Ignoring safety protocols can increase the likelihood of accidents and injuries in the workplace. Standard Operating Procedures for Radiology Room Preparation Decreased Efficiency: Lack of standardized processes can result in confusion and inefficiency, slowing down operations and increasing costs. Poor Training Outcomes: New employees may struggle to learn their roles without established procedures, leading to longer onboarding times and reduced productivity. Accountability Challenges: Without SOPs, it can be difficult to determine responsibility for mistakes, leading to conflicts and decreased morale. Diminished Continuous Improvement: Neglecting SOPs can hinder the organization's ability to gather data and feedback for process improvements. Responsibilities Radiology Technologists: Responsible for preparing the room and ensuring all equipment is functioning properly. Radiology Assistants: Assist in room preparation and maintenance of cleanliness. Radiology head of department: Ensure compliance with SOPs and provide training. Performing equipment cleaning Cleaning radiology equipment is crucial for maintaining hygiene, safety, and optimal performance. Here’s a step-by-step guide tailored for radiology settings: Before performing equipment you must consider Read Manufacturer Instructions Always check the equipment’s manual for specific cleaning recommendations Before cleaning make sure the equipment is turned off and do cleaning process eg wiping, dusting etc Make sure you dispose waste according to local regulations. Document Cleaning it can be a checklist containing ,cleaning activities, date, time, and person responsible. E.g. of steps of cleaning mashine Moisten some cotton wool with a solution and gently wipe the screen surface Wipe the equipment free of soap or cleaner with fresh cotton wool Wipe to dry Record date of cleaning Room Cleaning Initial Cleaning: Remove any used materials from the previous patient. Dispose of waste in designated containers. Disinfection: Wipe down all surfaces, including tables, control panels, and equipment handles, with approved disinfectants. Pay special attention to high-touch areas. Floor Cleaning: Sweep and mop the floor as necessary to maintain cleanliness Important of performing cleaning Preventing Damage Accumulated substances can damage sensitive components. Regular cleaning prevents corrosion and other forms of deterioration. Also can extend the lifespan of radiology equipment Infection Control Radiology equipment often comes into contact with patients, making it a potential source of infection. Regular cleaning helps reduce the risk of cross-contamination and the spread of pathogens. Professionalism A clean environment reflects professionalism and attention to detail, which can enhance patient trust and satisfaction. 4. Compliance with Health Standards Meets hospital hygiene policies, radiation safety regulations, and accreditation requirements. Helps avoid legal and regulatory issues. Patient Safety and Confidence A clean environment reassures patients and improves their comfort and trust. Minimizes exposure to contaminants, especially for immunocompromised patients. Performing Equipment Tube Warming and Calibration Performing Equipment Tube Warming and Calibration should be done as per manufacture instruction Tube warming is the process of allowing a tube (such as an X-ray tube, vacuum tube, or fluid-carrying tube) to gradually reach its normal operating temperature before full operation. Calibration is the process of adjusting and verifying an instrument’s measurements by comparing them against a known standard Importance of Tube Warming and Calibration in Radiology Tube Warming Prevents Damage to X-ray Tubes X-ray tubes in diagnostic imaging systems (especially high-output systems)

CRT04103 Radiographic Techniques and Procedures, Diagnostic Radiography NTA Level 4, Diagnostic Radiology Notes, NTA Level 4 Semester One

Spinal Trauma and Radiographic Assessment

DIAGNOSTIC RADIOGRAPHY · NTA LEVEL 4 · SEMESTER ONE Spinal Trauma and Radiographic Assessment CRT04103 · Radiographic Techniques and Procedures START READING NOTES Study Spinal Trauma and Radiographic Assessment using the sections below. Use the topic navigation to continue through Radiographic Techniques and Procedures. Contents of This Topic Spinal trauma: general considerations Spinal trauma: cervical spine Spinal trauma: cervical: reading a film Spinal trauma cervical: 4 parallel lines Spinal trauma cervical:important measurements Spinal trauma cervical : mechanisms Spinal trauma cervical; common injuries Spinal trauma cervical :extension injuries Spinal trauma: unstable cervical fractures Jefferson # Hangman’s # Flexion teardrop Clay shoveler’s # Unilateral locked facets Bilateral locked facets Anterior subluxation Thoracic spine trauma Chance # Spinal fracture -dislocation Spinal trauma: general considerations C7 is the most frequently Common sites of # are CI-C2, C5-C6, T10-12 In most spinal trauma, spinal cord damage occurs at time of injury AP, lateral views CT to clarify #s, MRI for soft tissue injury The spine Spinal trauma: cervical spine Cross-table lateral view, AP and open moth for odontoid, may also do Swimmers, Examine the cross table lateral first, before doing other views to avoid moving pt, if the lateral is normal, then do the rest of the series When no # is seen on all views and pain is present, do flexion and extension laterals CT clarifies the injuries Spinal trauma: cervical: reading a film All 7 vertebrae should be shown Check thickness of retropharyngeal space Asses the 4 parallel lines for discontinuity or step-off Examine the atlantodental interval ( distance from anterior arch of C1 to odontoid process of C2 Scrutinize disc space for narrowing or widening Spinal trauma cervical: 4 parallel lines Anterior vertebral line Posterior vertebral line Spinolaminar line Posterior spinous line ODONTOID PROCESS OF C2 SHOULD ALIGN WITH THE CLIVUS Anatomy of the cervical spine showing the 4 lines Spinal trauma cervical:important measurements Thickness of soft tissue plane anterior to C1-C3 < 5mm Thickness of soft tissue plane anterior to C4-C7 <20 mm Width of atlantodental interval < 3mm in adults and <5 mm in children (if wider impies torn transverse ligament) Spinal trauma cervical : mechanisms Hyperflextion Hyperextension compression Spinal trauma cervical; common injuries Subluxation Locked facets (unilateral or bilateral) Odontoid fractures Wedge fractures Clay- shoveler’s # Teardrop # Spinal trauma cervical :extension injuries C1 posterior arch Hangmans # Extension teardrop# Jefferson’s #( this is extension –compression) Spinal trauma: unstable cervical fractures Bilateral locked facets Odontoid # type 2 Teardrop Hangmans Jefferson Burst # Odontoid fractures Jefferson # Commpression # Bony ring of C1 Lateral mass is split, transverse lig. Is torn Axial force See displaced lateral mass of C1 beyond lateral margins of C2 Hangman’s # Traumatic spondylolisthesis of axis’ Hypersextension injury See bilatral pars interarticulatis #s of C2 See anterior dislocation of C2 body See antero-inferior avulsion # associated with a torn anterior longt. Lig. Prevertebral soft tissue shadow Hangmans # Flexion teardrop Severe flexion as when diving into shallow water Posterior lig. Disruption and anterior compression # of the vertebral body This is the most severe and unstable # of all spinal #s See anterior vertebral body avulsion resebling a tear drop See posterior vertebral body subluxation see # of spinous process See prevertebaral heamatoma associated with tear of ant.longtd. Lig Seen cord compression from fragments Flexion teardrop Clay shoveler’s # # of a spinous process often seen C6-T1 See spinous process #best seen on lateral view Ghost sign (double spinous process of C6 or C7 due to displaced fractures spinous process Unilateral locked facets Rotation injury of cervical spine resulting into tear of apophyseal joint ligaments and facet joint disclocation, making them lock See widening of the disc space (“Bow tie” or “ Bat wing” appearance of the locked facets Bilateral locked facets Due to extreme hyperflexion Complete anterior dislocation of the vertebral body High risk of cord injury See complete anterior dislocation of vertebrae Disrupted post.lontd. Lig an detachment of ant. Longtd.lig Bow tie or bats wing appearance of locked facets Anterior subluxation Disruption of post. Longtd. Lig complex from hyperextension May be stable or unstable Do basic views, plus flexion and extension views See fanning or widening of interspinous distance Anterior displacement of vertebral body Thoracic spine trauma # classified into compression (caused by anterior or lateral flexion) and burst (caused by axial loading or acute flexion) Compression # appears as wedging of the vertebral body. It is typically stable # Burst # (#lines extend throught the vertebral body to involve at times the post elements. Fragments in the vertebral canal cause cord compression. See a communited vertebrae, look for fragments in canal, widened interpeduncular distances Chance # Trabsverse splitting of the vertebral body and post elements All the columns, ant, mid and post of the spine are involved Neurological defects occur if there is associated disclocation Associated with abdominal organ injury Common in MVI when using a lap belt only Spinal fracture -dislocation Compression, distraction, and rotation injury Extremely unstable associated with neurological and abdominal organ damage ← PREVIOUS TOPICNEXT TOPIC →VIEW ALL MODULE NOTESVIEW SEMESTER NOTESVIEW ALL LEVEL NOTESALL DIAGNOSTIC RADIOLOGY NOTES Need These Notes as PDF? Need a clean, well-formatted PDF copy for offline study, revision or printing? Request the complete notes directly through WhatsApp. GET WELL-FORMATTED PDF NOTES

banner
Scroll to Top